    Size Exclusion HPLC Columns


    Size exclusion chromatography (SEC) is the most practical method of characterizing the molecular weight (MW) and molecular weight distribution of synthetic polymers, biopolymers and natural polymers. It is also known as gel permeation chromatography (GPC) or gel filtration chromatography (GFC). The pore size, pore size distribution and pore volume of media of size exclusion column have great effects on the separation of polymers. Hydrocell GPC 1500 column is produced from a single batch of wide pore distribution of polystyrene-divinylbenzene (PS-DVB) beads with the average particle size of about 10 m. It will provide more consistent results of analysis and separation of synthetic polymers.

    Overlay of GPC chromatograms of polystyrene standards for Polymer Labs PL-gel, mixed-D,
    5 m linear column (black) and BioChrom GPC 1500 column (red) in THF.

    HYDROCELL GPC 1500, 10 m PL-Gel, Mixed-D, 5 m Linear
    Column Size: 7.8 x 300 mm Column Size: 11.2 x 300 mm
    Sample: Polystyrene Standard Sample: Polystyrene Standard
    Eluent: THF Eluent: THF
    Detection: RI Detector Detection: RI Detector
    Flow Rate: 0.5 ml / min

    Flow Rate : 0.5 ml /min

    ViewViewView

    Hydrocell GPC 3000 Column is produced from a single batch of wide macropore of polystyrene-divinylbenzene beads with the average particle size of 10 m. The column is designed for analysis and purification of high molecular weight of synthetic polymers. High speed GPC 3000 HS, 150 x 7.8 mm column is designed for high through-put analysis and purification of high molecular weight synthetic polymers at 3 to 5 minutes.

    Major Advantages:

    • High Speed Separation of Polymers at 3 to 5 Minutes
    • High Resolution for High Molecular Weight of Synthetic Polymers
    • Single Batch of Wide Macropore of Polymer Beads
    • High Pore Volume